49. Steel wire ropes shall be:
1°  replaced when one of the following conditions exists:
a)  instructions of the ride manufacturer require it;
b)  6 wires are broken in one rope lay;
c)  3 wires are broken in one strand of a rope lay;
d)  2 wires are broken in a suspension rope which supports the total load of a carrier;
e)  the initial diameter of the rope has decreased by 10%;
f)  the rope is distorted because of kinking, crushing or untwisting of the rope or of a strand;
2°  repaired where 2 wires are broken near a fastening.