87.25.Seepage area: The total seepage area of a leaching field consisting of a seepage bed for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
Number of Total absorption area (square metres) bedrooms __________________________________________________________________
Disposal site Disposal site Disposal site is is of high is of permeable of permeable of permeability soil low permeability soil soil _________________________________________________________________
In other cases, the total seepage area of a leaching field consisting of a seepage bed must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
Total daily Total absorption area (square metres) flow (litres) __________________________________________________________________
Disposal site Disposal site Disposal site is is of high is of permeable of permeable of permeability soil low permeability soil soil __________________________________________________________________
0 to 540 7 14 35 __________________________________________________________________
541 to 1080 11 22 54 __________________________________________________________________
1081 to 1620 16 32 81 __________________________________________________________________
1621 to 2160 22 44 108 __________________________________________________________________
2161 to 2700 27 54 135 __________________________________________________________________
2701 to 3240 32 64 162 __________________________________________________________________
O.C. 786-2000, s. 69; 306-2017O.C. 306-2017, s. 511.
87.25.Seepage area: The total seepage area of a leaching field consisting of a seepage bed for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
Number of Total absorption area (square metres) bedrooms __________________________________________________________________
Disposal site Disposal site Disposal site is is of high is of permeable of permeable of permeability soil low permeability soil soil _________________________________________________________________
The total seepage area of a leaching field consisting of a seepage bed for another building must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
Total daily Total absorption area (square metres) flow (litres) __________________________________________________________________
Disposal site Disposal site Disposal site is is of high is of permeable of permeable of permeability soil low permeability soil soil __________________________________________________________________
0 to 540 7 14 35 __________________________________________________________________
541 to 1080 11 22 54 __________________________________________________________________
1081 to 1620 16 32 81 __________________________________________________________________
1621 to 2160 22 44 108 __________________________________________________________________
2161 to 2700 27 54 135 __________________________________________________________________
2701 to 3240 32 64 162 __________________________________________________________________